Product Overview

 

The Industrial EDI (Continuous Electrodeionization) Pure Water System combines Reverse Osmosis (RO) with electro-deionization technology to continuously produce high-purity and ultrapure water without chemical regeneration downtime.


Applicable Industries: Semiconductor manufacturing, pharmaceutical preparation, precision chemical processing, high-pressure boiler feed, and analytical laboratories.


Core Processing Capacity: Continuous water production with resistivity up to 18.2 MΩ·cm at 25°C, operating at flow rates from 0.5 m³/h to 50 m³/h.

 

 
  • High Purity Water Treatment Systems for Pharmacy
    Processing technology: reverse osmosis
    RO membrane: USA DOW
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software -- WAVE
    Stable operation & water...
  • EDI Water Purification System for Bioengineering
    Processing technology: Double pass RO & EDI
    Components brand: DOW membrane & Ionpure EDI & CNP pump
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software...
  • RO EDI Water Treatment System
    Processing technology: double pass RO + EDI
    RO membrane: USA DOW
    EDI module: USA Ionpure
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software --...
  • EDI Water Purification Plant for Semi-conductor
    Application: Semi-conductor
    Feed water: municipal tap water or underground water
    Processing technology: Pretreatment + double pass RO + EDI +
    RO membrane: DOW or VONTRON...
  • EDI Water Treatment Plant for Polysilicon
    Application: Polysilicon industry
    Key tech: reverse osmosis + EDI + PMB
    Membrane: DOW or VONTRON RO membrane
    EDI module: Ionpure
    System design: USA DOW software – WAVE...
  • EDI Purified Water System for Bio-medicine
    Processing technology: reverse osmosis & EDI
    RO membrane: USA DOW
    EDI module: Ionpure
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software --...
  • Edi Water Treatment System for Cosmetics
    Processing technology: Double pass RO & EDI
    Components brand: DOW membrane & Ionpure EDI & CNP pump
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software...
  • Edi System for Water Purification
    Processing technology: double pass RO + EDI
    RO membrane: USA DOW
    EDI module: USA Ionpure
    Membrane maintenance: CIP cleaning system
    RO design basis: USA DOW software --...
  • Edi Water Plant for Electronics Assembly
    Feed water: municipal tap water or well water
    Processing technology: Pretreatment + double pass RO + EDI
    RO membrane: USA DOW
    EDI module: USA Ionpure
    Membrane...
  • Ro Edi System for Food Processing
    Application: hair dye manufacturing
    Key tech: reverse osmosis
    Membrane: DOW or VONTRON RO membrane
    Pump: CNP
    System design: USA DOW software – WAVE & 20 years...
 

System Types & Configurations

 

 

Single-Pass RO + EDI System:

Standard configuration designed for general industrial applications requiring resistivity between 1.0 MΩ·cm and 15.0 MΩ·cm.

 

Two-Pass RO + EDI System:

Engineered for high-purity applications (such as microelectronics and pharmaceutical purified water), effectively removing trace silica, boron, and total organic carbon (TOC).

 

Skid-Mounted Modular System:

Pre-assembled on a powder-coated carbon steel or 304/316L stainless steel skid, integrating pre-filtration, RO units, EDI modules, chemical dosing, piping, and electrical control cabinets into a compact footprint.

 

 

Key Specifications

 

Parameter

Standard Industrial Model

High-Purity Laboratory Model

Unit

Output Flow Rate

1.0 – 50.0

0.5 – 5.0

m³/h

Product Water Resistivity

≥ 10.0 (at 25°C)

≥ 18.2 (at 25°C)

MΩ·cm

Total Organic Carbon (TOC)

< 50

< 20

ppb

Silica (SiO₂) Removal Rate

≥ 99.0

≥ 99.9

%

System Recovery Rate

75 – 85

70 – 80

%

Max Feedwater Conductivity

< 40 (RO Permeate)

< 10 (RO Permeate)

μS/cm

Feedwater SDI₁₅

< 3.0

< 2.0

—

 

 
 
Applications

Electronics & Semiconductor:

Ultrapure rinse water for silicon wafer fabrication, printed circuit boards (PCBs), and electronic components.

Pharmaceutical & Medical:

Feedwater for purified water storage loops, USP/EP water pre-treatment, and biomedical laboratory testing.

Analytical Laboratories:

Reagent preparation, high-performance liquid chromatography (HPLC), and mass spectrometry.

Industrial Manufacturing:

High-pressure turbine boiler makeup water, optical coating rinsing, and fine chemical synthesis.

 

EDI Water Purification System For Bioengineering

 

Customization & System Integration

Systems are engineered to match exact facility conditions and user specifications:


Feedwater Adaptation: Pre-treatment integration (multimedia filtration, activated carbon adsorption, water softening, or ultrafiltration) customized to local raw water analysis.


Piping & Materials: Sanitary 316L stainless steel fluid-contact piping featuring orbital welding and internal electropolishing (Ra ≤ 0.4 μm), or high-purity heat-fused PVDF/PP piping.


Automation & Control: PLC-based architecture (Siemens S7-1200/1500 or Allen-Bradley) with industrial HMI touchscreens, real-time telemetry for resistivity, flow, pressure, and temperature, plus integration capability with plant SCADA via Modbus/Ethernet.

 

Manufacturing & Quality Control
 

Component Traceability:

Built with globally recognized industrial components, including certified EDI modules (Evoqua, SnowPure, or Ionpure), high-pressure multi-stage centrifugal pumps (Grundfos), and sanitary instrumentation.

Fabrication Standards:

Structural frames welded by certified technicians (ASME Section IX); automatic orbital welding applied to all stainless steel fluid paths to prevent dead legs and bacterial growth.

Factory Acceptance Testing (FAT):

Every system undergoes hydrostatic pressure testing, electrical safety checks, PLC input/output logic simulation, and dry/wet operational runs prior to crating. Deliverables include P&ID schematics, electrical wiring diagrams, material mill test reports, and FAT inspection certificates.

 

 

Frequently Asked Questions

 

 

Q: How do I select the correct system flow rate?

A: Calculate your peak hourly demand and total daily consumption, then add a 15% to 20% safety margin. Storage tank sizing should also be factored in to balance intermittent high-volume draws with continuous system production.

Q: Does the system support continuous 24/7 operation?

A: Yes. Industrial configurations are engineered for uninterrupted round-the-clock operation, utilizing automated flush cycles and multi-train redundancy to maintain steady output.

Q: What is the typical service life of the EDI module?

A: When operated under compliant feedwater parameters (RO permeate hardness < 1 ppm, SDI < 3, and free chlorine < 0.05 mg/L), EDI modules operate stably for 5 to 8 years without requiring replacement.

Q: What are the strict pretreatment requirements before the EDI module?

A: EDI feed water must meet rigorous thresholds: RO permeate conductivity < 40 μS/cm, SDI₁₅ < 3, total hardness < 1 ppm (as CaCO₃), and complete removal of oxidizing agents such as chlorine and ozone.

Q: Does this system require hazardous chemical regeneration?

A: No. Unlike traditional ion-exchange resin columns that require hazardous hydrochloric acid and sodium hydroxide for regeneration, EDI utilizes direct current to continuously regenerate the ion-exchange resin internally.

Q: What documentation is supplied with the equipment?

A: Standard documentation package includes comprehensive user manuals, P&ID drawings, electrical schematics, instrument calibration certificates, FAT reports, and 3.1 material traceability certificates for wetted metal components.

 

modular-1
Request a Quote

To receive a detailed engineering proposal and commercial quotation, provide the following parameters to our technical team:
Source Water Quality: Feedwater origin (municipal, well, or surface water) and incoming TDS or conductivity level.
Target Water Quality: Required resistivity (MΩ·cm) and maximum permissible TOC limit.
Operating Flow Rate: Required continuous flow rate (m³/h or GPM) and daily operating hours.
Site Constraints: Available installation footprint, facility power supply voltage, and preferred PLC control brand.

As one of the most professional edi pure water system manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to buy customized edi pure water system made in China here from our factory. Contact us for more details.

edi water treatment, edi water treatment machine, ro edi water machine
Send Inquiry